Good Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for Rubber

Product Details
Customization: Available
After-sales Service: Online or on-Site Service
Warranty: 1year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (25)
  • Good Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for Rubber
  • Good Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for Rubber
  • Good Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for Rubber
  • Good Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for Rubber
  • Good Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for Rubber
Find Similar Products

Basic Info.

Model NO.
CS8820T
Measuring Range
C: 0.0001%-10.0000% S: 0.0001%-3.5000% (Can Extend
Electronic Balance
Weight The Sample in Variable Amount Accuracy of
High Frequency Furnace
Power ≥2.7kVA Oscillation Frequency:20MHz
Analysis Time
25-60 Seconds Can Be Set ( Usually 35 Seconds)
Power Supply
Voltage:AC220V±5%, Frequency:50Hz±2%
Oxygen
Purity: ≥99.5%, Input Pressure : 0.18MPa + 5%
Transport Package
Wooden Package
Trademark
wuxi jinyibo
Origin
Jiangsu Wuxi
HS Code
9027300090
Production Capacity
30 Sets/Month

Packaging & Delivery

Package Size
142.00cm * 77.00cm * 110.00cm
Package Gross Weight
210.000kg

Product Description

Product Description
Testing the mass fraction of C,S of steel,iron,alloy,mold and cores,nonferrous metal,cement,ore,coke,catalyst,magnetic materials,ceramic,inorganic,substance,black lead,refractory matter,battery matter,plant and other material.
Main Features
(1).Adopting the double CPU up and down modual design, elestronic circuit integration degree is highly, steady and reliable, which can settle the high-frequency interference thoroughly.

(2).The special new platinum infrared light source,Gold plated carbon sulfur analysis pool and high precision pyroelectric infrared detector to make the apparatus' measurement more accurate.

(3).Adopting the high power and quick frequency circuit design, which using 6KVA high frequency power tube(actual use of power is about 2.5KVA, it can turn on to work itself), to reduce the high frequency combustion system load and to increase the using time.

(4).Furnace head automatic cleaning device, patent technology supply system and -0.4mm amd hole metal filter to make the dust and gas seperated, reducing the dust on the result of analysis.

(5.)Specialized analysis software of many different language owns following functions:curve/data storage, blank deduction, parameter determination, channel choosing, data statistics, results correction, breakpoint correction, curve comparison, system diagnosis, automatic/manual printing analysis results etc.
 Main technical parameter

Measuring range

Carbon: 0.0001%-95.0000% (can be expanded to 99.9999%)
Sulfur: 0.0001%-95.0000% (can be expanded to 99.9999%)
Low carbon:1ppm~0.2%, high carbon:0.2%~99.99999% (low carbon and high carbon automatic adjustment)
Low sulfur:1ppm~0.2%, high sulfur:0.2%~99.99999% (low sulfur and high sulfur automatic adjustment)

Analysis of error

With GB / T20123-2006/ ISO15350: 2000 standard

Analysis time

25-60 seconds can be set ( usually 35 seconds)

High frequency furnace

power ≥2.7KVA Oscillation frequency:20MHz

Electronic balance

weight the sample in variable amount  Accuracy of reading:0.0001g

Working environment

indoor temperature:10-30ºC,relative humidity:<90%

Power supply

voltage:AC220V±5%,frequency:50Hz±2%

Oxygen

Purity: ≥99.5%,  input pressure : 0.18MPa + 5%


Good Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for RubberGood Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for RubberGood Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for RubberGood Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for RubberGood Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for RubberGood Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for RubberGood Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for RubberGood Analytical Performance High-Frequency Infrared Carbon Sulfur Analyzer for Rubber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier