Laser Absorption Spectroscopy for Carbon Portable Spectrometer

Product Details
Customization: Available
Detector: Passively Q-Switch Solid-State Laser
Analysis Range: 0.1ppm-99.99%
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (25)
  • Laser Absorption Spectroscopy for Carbon Portable Spectrometer
  • Laser Absorption Spectroscopy for Carbon Portable Spectrometer
  • Laser Absorption Spectroscopy for Carbon Portable Spectrometer
  • Laser Absorption Spectroscopy for Carbon Portable Spectrometer
  • Laser Absorption Spectroscopy for Carbon Portable Spectrometer
Find Similar Products

Basic Info.

Model NO.
Expert 2 C+
Power Supply
220V Adapter, 16.8V 3A Output, and Lithium Cell(43
Analysis Elements
C-U
Weight
1.25kg(with Battery)
Application
Fabrication, PMI, Recycling, Sorting, Trading
Simultaneous Analysis
Analysis 0f 10 Elements
Transport Package
Carton Package
Specification
1.25kg
Trademark
wuxi jinyibo
Origin
Jiangsu Wuxi
HS Code
9027300000
Production Capacity
5 Sets/Month

Product Description

Expert 2 C+ Portable LIBS Analyzer

Advanced Portable LIBS Analyzer for Carbon in Steels

Specification:

The technology of laser analyzes carbon
Carbon in Low Alloy Steel, Stainless Steel, Cast Iron
Quick results display
Portable device capable of analyzing carbon
No sample processing
Low owner cost
Portable LIBS Analyzer for carbon

Summary:

The Expert 2 C+ uses the technique laser induced breakdown spectroscopy (LIBS), which has many similarities to spark OES. When a pulse of laser light is focused and projected onto the surface of the test sample, the generated excited plasma emits characteristic light radiation with a specific wavelength. LIBS uses sensitive spectrometer analysis to get the types and corresponding contents of elements in the material. LIBS technology does not require sampling and sample preparation, and its destructiveness on the sample surface is negligible. Due to the technical difficulty, only a few companies in the world can produce carbon measuring portable LIBS equipment.

Key Applications:

Carbon is one of the most common elements in nature. In mining, metal smelting, material manufacturing and other links, carbon is inevitably introduced into metal materials, it has an important influence on the mechanical properties of metals and manufacturing processes, so accurate detection of carbon content in metals is of great significance.

Features:

Excellent Portability

The Expert 2 C+ Portable LIBS Analyzer for carbon weighs only 2.5Kg, and the operator can easily lift it with one hand. It is equipped with a high-capacity lithium battery and a miniature mobile argon gas cylinder, which is convenient for use in small spaces and various production sites. It can effectively judge carbon steel, low alloy steel, stainless steel and other Metal brands, element content analysis, and distinguish materials that use carbon as the distinguishing element.

Excellent Analysis Function

The Expert 2 C+ Portable LIBS Analyzer can solve the testing requirements of customers in the entire process of alloy processing and manufacturing, such as quality control, material classifcation, safety precautions, accident investigation, etc. Whether it is ferrous metal or non-ferros metal, portable LIBS Analyzer can quickly and accurately give accurate and reliable test data to obtaion reliable analysis results.

High-purity Argon and Purge

Argon purge is vital for quantitative analysis with LIBS Analyzer and Optical Emission Spectrometer, and it is also very important for carbon. for carbon. So, the technique argon is a key component for measuring carbon accurately. The laser beam is small in diameter, thus a very small purge volume is needed for the argon purge. The Expert 2 C+ use about 1000 times less argon than a spark OES. So, this is a cost-saving option.

High Laser Pulse Energy and Frequency

The high energy and high rep rate laser rapidly burns off surface contamination in order to get a good analysis. A good grind and pre-burn is as critical for LIBS analysis as it is for spark Optical Emission Spectrometer (OES).

Laser Raster

Rastering is a must for accurate carbon tests with LIBS. The laser is typically 100 um diameter beam and even the best sample prep may not completely remove surface contamination on this distance scale. The Expert 2 C+ moves the laser to different spot, the carbon algorithm then examines the resulting data from each location.

Parameter:

Core Technology It is based on laser induced breakdown spectroscopy, It uses a safe Class 3B laser
Size 230mm*170mm*170mm
Weight 2.5Kg
Power Supply 220V adapter, 16.8V 3A Output, and Lithium Cell(43Wh)
WIFI 2.4GHz, 802.11n/b/a wireless network
Bluetooth Bluetooth 4.1 Classic, Bluetooth Low Energy
Display Screen 7.0 Inch capacitive touch screen, HD resolution
Memory Unit 8Gb, 16 Gb
Single test time 6~8 S
High-precision test mode It can analyze the average value of multiple single test values through an algorithm
Alloy Base Carbon steel, Carbon-containing alloy steel, Low-alloy steel, and Stainless steel
Element Al, C, Co, Cr, Cu, Mn, Mo, Ni, Si, Ti, W
Sample Type Solid, wire with diameter above 1mm, foil, large fragments
Detection Limit (%)
Al 2.0
C 5.0
Co 0.3
Cr 27.0
Cu 1.0
Mn 15.0
Mo 6.0
Ni 15.0
Si 5.0
Ti 3.0
W 15.0
Protective Gas High purity argon
Gas Cylinder Device Various portable capacity options(0.025L~1.0L)

 

Laser Absorption Spectroscopy for Carbon Portable Spectrometer


Packing & Shipping
Laser Absorption Spectroscopy for Carbon Portable Spectrometer
Laser Absorption Spectroscopy for Carbon Portable Spectrometer
Laser Absorption Spectroscopy for Carbon Portable Spectrometer
Laser Absorption Spectroscopy for Carbon Portable Spectrometer
Laser Absorption Spectroscopy for Carbon Portable Spectrometer
Laser Absorption Spectroscopy for Carbon Portable Spectrometer


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier