Rapid High Frequency Infrared Carbon Sulfur Analyzer for Metal Analysis

Product Details
Customization: Available
After-sales Service: Online or on-Site Service
Warranty: 1year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (25)
  • Rapid High Frequency Infrared Carbon Sulfur Analyzer for Metal Analysis
  • Rapid High Frequency Infrared Carbon Sulfur Analyzer for Metal Analysis
  • Rapid High Frequency Infrared Carbon Sulfur Analyzer for Metal Analysis
  • Rapid High Frequency Infrared Carbon Sulfur Analyzer for Metal Analysis
  • Rapid High Frequency Infrared Carbon Sulfur Analyzer for Metal Analysis
Find Similar Products

Basic Info.

Model NO.
CS-8820T
Element
Carbon and Sulfur Elements
Analysis
Infrared Analysis
Display
Computer Screen
Application
Steel, Iron, Alloy, Non-Ferrous, Cement, Ore, Coke
Frequency
50Hz±2%
Performance
Automation
Function
Element Content Test
Weight
100-500Kg
Power Source
AC220V±5%
Customized
Customized
Patent
Co Translates Into CO2 Device
Min. Reading
0.1ppm
Analysis Time
20 -100s, Usually 35s
Transport Package
Wooden Package
Trademark
wuxi jinyibo
Origin
Jiangsu Wuxi
HS Code
9027809900
Production Capacity
20 Sets/Month

Packaging & Delivery

Package Size
142.00cm * 77.00cm * 110.00cm
Package Gross Weight
210.000kg

Product Description

Product Description
Testing the mass fraction of C,S of steel,iron,alloy, mold and cores,non-ferrous metal,cement,
ore,coke,catalyst,magnetic materials,ceramic,inorganoc substance,black lead,refractory matter,battery,plant and other materials.
3. Main technical parameters

Analysis theory:high-frequency furnace burn infrared absorptive detection.

Range of measurement:C:0.00001%-10.0000% (can extend to 99.99999%)  

                                              S:0.00001%-6.0000% (can extend to 99.99999%)
Analytical error:accord with GB/T20123-2006/ISO15350:2000 standard

Analysis precision:C:RSD≤0.5 %      S:RSD≤1.0%

Sensibility (Min. reading):0.1ppm

Detection pond:C:C Pond (can add low C pond )  

                               S:S Pond ( can add High S pond )

Time of analysis:20-100s can setting(usually 35s)

High -frequency furnace:power ≥2.7KVA  Oscillation frequency:20MHz

Electronic balance:weight the sample in variable amount  

                                     Accuracy of reading:0.0001g

Work environment:indoor temperature:10-30°C,

                                    relative humidity:<75%,

                                    voltage:AC220V±5%,

                                    frequency:50Hz±2%

The key characteristics

The instrument imports the advanced technology from abroad, is a high-tech product with integration of light, machine, electricity, sensors, computers and analysis technology etc. Measurement range is extensive, antijamming capability is powerful, all-ready function, easy to operate, the analysis result is exact and reliable etc. Most components of the instrument are imported from abroad, and the machine is comparable with imported products. 

(1) Humanized circular arc and stainless steel table-board design, easy to operate.

(2) Domestic pioneering double carbon and double sulfur pool access to analysis the ultra low and higher content, and automatic switching.

(3) High-speed sampling 24 realizes the dynamic data integral of analysis procedure; improve the analysis sensitivity and accuracy rating.

(4)CO translates into CO2 device(only domestic owns), improves the degree of accuracy of measuring the C.

(5) Use7.5KVA high-frequency ceramic power tube, burn the samples adequately and its stability is good.

(6) Snap-in type automatic sweep technique ( with patent ) and ultramicropore mental dust filter,reducing the influence of dust to analysis result, easy to dismantle, be in favor of maintain.

(7) Low tension heating ring ( with patent technology) heating in furnace end, which can improve the percent conversion and stabilize the analysis result of S.

(8)Infrared detection part and high-frequency furnace are connected by optical (domestic pioneering),coordinate with multilevel covert style isolation circuit,which can avoid the high-frequency interference thoroughly.

Analysis Software

(1) Operational software: Adopt Deliph software compiler, and WINDOWS Xp English operating software.

(2) Analysis channel:Provide channel management function,C&S channel can add, delete and edit by itself, no quantitative restriction, preset low carbon and high-sulfur interface,realize the automatic switchover of software.

(3) Analysis functions: Analysis procedure dynamic data integral, sampling 24 times/s, improve the sensitivity and accuracy rating of analysis, manage the sample, including edit the name, logo of samples, increase and delete sample name. The software provides multi-user management system, the manager can sset up different user rights. 

(4) Show function: C and S hold a curve box respectively; show the real-time data and C & S release curve in the analysis process dynamically.

(5) Print function: multiple print mode, the two print modes-laboratory and check station are provided, and it can plan print format by itself.

(6) Self diagnosis function: System diagnosis, detecting sealing of the furnace head and gas chamber by software. 

(9) Dedusting and decontamination plant adopt internal pressure seal, tightness and purification effect is good, easy to replace.

(10) WINDOWS Xp English operating interface, the analysis software adopts Deliph software compiling, function setup is powerful, and the interface is distinct and visualized.

(11) Powerful data statistics function, networking operation, data transmission on the internet and number off.

Rapid High Frequency Infrared Carbon Sulfur Analyzer for Metal AnalysisRapid High Frequency Infrared Carbon Sulfur Analyzer for Metal AnalysisRapid High Frequency Infrared Carbon Sulfur Analyzer for Metal AnalysisRapid High Frequency Infrared Carbon Sulfur Analyzer for Metal AnalysisRapid High Frequency Infrared Carbon Sulfur Analyzer for Metal AnalysisRapid High Frequency Infrared Carbon Sulfur Analyzer for Metal AnalysisRapid High Frequency Infrared Carbon Sulfur Analyzer for Metal Analysis

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier