Customization: | Available |
---|---|
Analysis Speed: | 10 Elements Per Minute |
Precision: | Rsd (Relative Standard Deviation) ≤2% |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(1). Analysis Speed: 10 elements per minute;
(2). Precision: RSD (relative standard deviation) ≤2%;
(3). Stability: RSD (relative standard deviation) ≤3%(testing one hour);
(4). Measurement range of linearity: related coefficient ≥0.9995%;
(5). Detection limit is low: representative element detection limit as follows.
The detection limit of 36 elements (ug/ml)
Element Wavelength(nm) Detection limit
Element Wavelength(nm) Detection limit
Element Wavelength(nm) Detection limit
Element Wavelength(nm) Detection limit |
La 408.672 3.0
Ho 345.600 3.0
Mn 257.610 3.0
Ca 393.366 1.0 |
Ce 413.765 5.0
Er 337.271 3.0
Mg 279.553 1.0
Mo 281.615 5.0 |
Pr 414.311 5.0
Tm 313.126 3.0
B 249.773 10.0
V 310.230 5.0 |
Nd 401.225 5.0
Yb 369.419 1.0
Zn 213.856 3.0
Be 313.041 1.0 |
Sm 360.946 10.0
Lu 261.541 3.0
Co 228.616 3.0
Ti 344.941 3.0 |
Eu 381.967 1.0
Y 371.050 1.0
Si 251.611 10.0
Cu 324.754 3.0 |
Ga 342.247 10.0
Sc 335.373 1.0
Ni 232.003 5.0
Cr 267.716 5.0 |
Tb 350.917 3.0
Ta 226.230 5.0
Cd 226.502 3.0
Al 396.152 5.0 |
Dy 353.170 3.0
Nb 316.340 5.0
Fe 239.562 3.0
Zr 343.823 5.0 |
Radio-frequency signal generator (RF)
Inductive feedback type self-oscillation circuit, coaxial-cable output.
Match and tune, take the power feedback to proceed automatic closed-loop control.
Samples introduce system.
Three concentric quartz torch tubes.
Scanning optical splitter.
1000mm/750mm focal distance ion etching holographic grating.
Main features
(1). High stability of RF (radio frequency) output, light source is stable, detection limit is low, the minimum value can be reaching PPb (Parts per Billion).
(2). The range of linearity of the work curves is wide, which can reach from 5 to 6 orders of magnitude.
(3). Multi-elements analysis at the same time, fast and application area is wide. It can analyze all the metallic elements and some nonmetallic elements of the periodic table of elements.
Software Introduction:
TY-9800 Type ICP Spectrometer uses analysis & operation software, operation is convenient and fast, function is powerful, test, data processing, correction and data output etc. can be realized at the same time.
Software function includes standard curve,search the peak automatically, build analytical method.
Packing & Shipping