• Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
  • Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
  • Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements

Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements

After-sales Service: Online or on-Site Service
Warranty: 1year
Frequency: 27.12MHz
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements pictures & photos
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
US $53,700-55,400 / Set
Min. Order: 1 Set
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Jiangsu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (25)

Basic Info.

Model NO.
TY-MICS
Precision
2ppm, Mixed Multi-Element Solution, Rsd≦1%
Stability
2 Hours Rsd≦1.5%
Spectral Line Flexibility
Semi-Quantitative and Quantitative Analysis
Type
Solid-State High-Frequency RF Generator
Power Supply Features
with RF Power Reverse Power Protection
Output Power
500-1600W
Wavelength Response Range
165nm~1000nm
Focal Length
1000mm
Resolution
≤0.008nm
Transport Package
Wooden Package
Trademark
wuxi jinyibo
Origin
Jiangsu Wuxi
HS Code
9027300090
Production Capacity
20 Sets/Month

Packaging & Delivery

Package Size
183.00cm * 96.50cm * 104.50cm
Package Gross Weight
300.000kg

Product Description

Plasma observation mode: Torch tube placed vertically
Peristaltic pump: 5-channel & 16-roller peristaltic pump.
Analytical speed: ≥50 elements or spectral lines per minute and integration time≥10 seconds per measured spectral line;
Spectral line flexibility: any of the analyzed elements can be qualitative, semi-quantitative and quantitative analysis of any one of the spectral lines, to facilitate the
Analyzing and researching.
Precision: Analyzing of 1ppm or 10ppm multi-element mixed standard solutions. Repeatability of data RSD≤0.5%.
Stability: Analyzing of 1ppm or 10ppm multi-element mixed standard solutions.RSD <1.0% for 4 hours of continuous measurement without internal standard calibration.

Summary:
ICP-OES TY-MICS series full-spectrum direct-reading inductively coupled plasma emission spectrometer is a brand-new generation of ICP-OES products based on many years of experience in developing spectroscopic instruments by JINYIBO Instrument Technology Co.,Ltd. Using the reliable integrated solid-state RF power supply, solid constant-temperature two-dimensional spectroscopy system, scientific research level cooling anti-overflow CCD detection system, combined with the domestic leading spectral calibration technology, the operability, flexibility and reliability of ICP-OES MICS is beyond imagination, and the daily operation and maintenance is very simple, which is more suitable for the operation requirements of the first-line analysis experiments in China, and realizes Miniatorization, Intelligentize and Convenicnce of Spectrometcr.

Applications:
Geology and Mining: Accurately and quickly analyzing the elemental content in mines is of strict significance in guiding the mining of mines in the early stage, control in the middle stage, and restoration in the later stage, and so on.
Precious metals: the content of impurity elements in precious metals directly affects the purity and performance of precious metals, and at the same time determines the value of the precious metals themselves, accurate determination of the content of low-content impurity elements is extremely important to the precious metals industry.
Environmental protection: Accurately and quickly analyze heavy metal elements in environmental samples (water quality, soil) to protect human daily life. Toys and consumer goods industry: Analyzing heavy metal elements in children's toys and consumer goods ensures that the heavy metal element content of the products produced is within the control range, so that children and parents can feel more at ease.
Petrochemicals: Accurate measurement of elemental content in petrochemical products (gasoline, diesel, lubricants), elemental analysis of raw materials and finished products in the chemical industry to ensure that the production process is in line with quality control.
Toys: Analysis of heavy metal elements in children's toys to ensure that the heavy metal element content of the products produced is within the control range, so that parents and children can feel more at ease.
Metallurgy: The analysis of product composition can be used to control the production process and technology in real time to ensure that the composition content of the final product to ensure the quality requirements of the final product.

Features:
Real time monitoring system for plasma flames
Equipped with a real-time full color camera system,the operatorcan see the running graphics of the plasma in real-time full colorin the control software of the instrument,and observe whether thetorch tube and the center tube of the torch tube are dirty and needto be cleaned.

Testing speed beyond imagination
A testing speed of 20s can be set to an appropriateintegration time for measurement;The integratedintensity values of all analytical spectral lines can beread out in one exposure;Accurate measurement ofnearly 70 elements in a single sample within one minute.

Convenient wavelength calibration function
Intelligent automatic wavelength calibration algorithm,the softwareautomatically performs wavelength calibration after startup,greatlysaving time and cost for wavelength calibration.

Fully automatic ignition and matching technology
The sofiware can fully automatically igniie with one click,and allparameter settings are aufomatically changed.With advancedautomatic matching technology,the ignition success rate is highand the operation is simple.

High degree of instrument automation
The automation level of the instrument is extremely high,and all operations except for the power switch arecompleted by software.Intelligent software that can provide real-time feedback and information prompts forvarious operations.

One second positioning of torch tube position
The torch tube auxiliary installation tool using patented technology can accurately achieve a concentric circlestructure between the torch tube and the coil position,while ensuring that there is no deviation in the positionand ensuring the stability of the test signal.

Separate injection system
The split design of the fog chamber and torch tubereduces the impact of temperature changes in thecombustion chamber on atomization efficiency,making it more intuitive to observe the real-timeinjection status.Equipped with patented technology,the extended mist chamber effectively separates gasand liquid,reducing interference from water vapor.



The detection limit of 36 elements (ug/ml)

Element Ta Nb Mn Mg B Zn Co Si
Wavelenth
(nm)
226.230 313.340 257.610 279.553 249.773 213.856 228.616 251.611
Detection limit <5.0 <5.0 <3.0 <1.0 <10.0 <3.0 <3.0 <10.0
Element La Ce Pr Nd Sm Eu Gd Tb
Wavelenth
(nm)
408.672 413.765 414.311 401.225 360.946 381.967 342.247 350.917
Detection limit <3.0 <5.0 <5.0 <5.0 <10.0 <1.0 <9.0 <3.0
Element Cu Cr Al Zr Ag Sr Au Pt
Wavelenth
(nm)
324.754 267.716 396.152 343.823 328.068 407.771 242.795 265.945
Detection limit <3.0 <5.0 <5.0 <5.0 <3.0 <1.0 <5.0 <5.0
Element Ni Cd Fe Ca Mo V Be Ti
Wavelenth
(nm)
232.003 226.502 239.562 393.366 281.615 310.230 313.041 334.941
Detection limit <5.0 <3.0 <3.0 <1.0 <5.0 <5.0 <1.0 <3.0
Element Dy Ho Er Tm Yb Lu Y Sc
Wavelenth
(nm)
353.170 345.600 337.271 313.126 369.419 261.541 371.030 335.373
Detection limit <3.0 <3.0 <3.0 <3.0 <1.0 <3.0 <1.0 <1.0
Element Pd Ir Rh Ru Ba Li Na K
Wavelenth
(nm)
340.458 224.268 343.489 240.272 455.403 670.784 588.995 766.490
Detection limit <5.0 <10.0 <10.0 <5.0 <1.0 ≤3 ≤20 ≤30
Element As Sb Bi Hg Pb Ga Os W
Wavelenth
(nm)
228.812 206.833 223.061 253.652 220.353 294.364 225.585 207.911
Detection limit ≤15 ≤15 ≤10 ≤15 ≤15 ≤10 ≤1 ≤10
Element Sn Te Ta Th Tl Re Ge Se
Wavelenth
(nm)
242.949 214.281 226.230 283.730 276.787 227.525 209.426 203.985
Detection limit ≤20 ≤10 ≤5.0 ≤10 ≤30 ≤5 ≤15 ≤15


Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
Packing & Shipping
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements
Accurate Ty-Mics Inductively Coupled Plasma Spectrometer for Heavy Metal Elements

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now