• Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System
  • Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System
  • Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System
  • Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System
  • Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System

Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System

After-sales Service: Available
Warranty: 1 Year
Magnification: <50X
Type: Video
Number of Cylinder: Binoculars
Mobility: Desktop
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Jiangsu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (25)

Basic Info.

Model NO.
CA45
Stereoscopic Effect
Stereoscopic Effect
Kind of Light Source
Ordinary Light
Shape
Single-lens
Usage
Research
Principle
Optics
Principle of Optics
Polarizing Microscope
Standard
ISO 16232 & Vda19
Image Mosaic Accuracy
≥1.0 Um
Scale
4.3801 Um/Pixel
Analysis Diameter[mm]
46.31
Particle Count
0.55%
Transport Package
Wooden Case
Specification
800mmX600mmX1300mm
Trademark
JINYIBO
Origin
China

Product Description

CA45 Technical Cleanliness Analysis System
High-performance Technical Cleanliness Inspection System

Fast, Accurate measurement data
Ease of use and efficient
Contaminant particles ranging from 2.5 µm up to 42 mm
Image stitching of large particles
Reproducible observation conditions
Results automatically classified

Summary
CA45 Technical Cleanliness Analysis System is a high-performance particle size testing system used in auto parts, aerospace, and hydraulic lubrication industries. It has the advantages of professional, standardization, and test results traceable. The system integrates imported optical microscope, high stable motorized stage, automatic analysis software, HD image scanning CCD, with high automation, workflow design mode, simple operation, capture images fast and efficient, automatic compensation and focus to ensure that each frame of image is clear, seamless browsing, Intelligent recognition statistics, and according to selection criteria generate results and reports. All the analysis process based on ISO16232, VDA19 and other standards to meet the cleanliness testing standards of major automobile factories such as Volkswagen, BMW, GM, Ford, and support user-defined standards.

Applications
CA45 Technical Cleanliness Analysis System full compliance with the requirements of VDA 19.1-2015, ISO 16232, ISO4406 and ISO 4407, QV11111 and customer-defined standards. Adopted optical polarization technology, manually rotate the polarization device, the metallic luster reflection properties of all pollutants on the entire filter can be determined by two scans. At the same time, according to the morphological definition of fiber in VDA19.1 (stretch length/maximum inscribed circle diameter>20, maximum inscribed circle diameter<=50 microns), the classification and classification of the following four types of particles can be quickly and automatically completed within a few minutes. Size measurement: reflective particles, reflective fibers, non-reflective particles, non-reflective fibers.

Microscopic image analysis
Scale 4.3801 μm/Pixel Analysis diameter[mm] 46.31
Particle count 26585 Filter membrane coverage 0.55%
Standard VDA19
Class X range μm Measured count (Without fiber) Measured count of metal Measured count of fiber Equivalent count (Without fiber) Equivalent count of metal Equivalent count of fiber
B 5<=X<15 11619 10 0 11619 10 0
C 15<=X<25 6954 14 0 6954 14 0
D 25<=X<50 5477 49 0 5477 49 0
E 50<=X<100 1775 97 0 1775 97 0
F 100<=X<150 406 134 0 406 134 0
G 150<=X<200 158 105 0 158 105 0
H 200<=X<400 139 118 19 139 118 19
I 400<=X<600 10 9 8 10 9 8
J 600<=X<1000 6 6 6 6 6 6
K 1000<=X<1500 2 2 5 2 2 5
L 1500<=X<2000 0 0 1 0 0 1
M 2000<=X<3000 0 0 0 0 0 0
N X>=3000 0 0 0 0 0 0

Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System

Packing & Shipping
Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System
Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System
Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System

Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System
Technical Cleanliness Analysis with Automatic (Motorized) Optical Particle Analysis System



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2007-10-16
Management System Certification
ISO9001:2015